How to choose enterprise storage
How to put together storage requirements: data and workload types, block, file and object storage, all-flash or hybrid, capacity, resilience, the hyperconverged alternative, support and service life.
On this page
Storage is bought for five years or so, and a wrong choice doesn’t show right away. The system goes live and runs fine, and then at peak hours it can’t keep up with the database. Or it runs out of space a year earlier than planned. That’s why requirements come first and the vendor catalog later.
Data and workloads
Write down the systems that will use the storage and, for each, how it accesses data. They usually fall into a few groups.
- Databases and virtual machines. Lots of small operations, and every millisecond of latency is felt.
- File shares for departments and branches, with shared folders, access rights and quotas.
- Backups and archives: large volumes that are rarely accessed.
- HPC/AI data, meaning large datasets read by dozens of compute nodes at once.
For each group, agree RPO and RTO with the business process owners. RPO is how long a period of data just before an outage you can afford to lose (NIST (opens in a new tab)). RTO is how quickly a system must be running again before downtime harms the organization’s work (NIST (opens in a new tab)). They’ll show whether nightly backups are enough or whether you’ll need frequent snapshots (point-in-time copies of data) and replication (copying data) to a second site.
Block, file and object storage
A server sees block storage as its own disk. It is often deployed in a storage area network (SAN), and typical uses are databases and virtual machine volumes (IBM (opens in a new tab)).
File storage is the familiar folder tree, reached over the network via SMB and NFS. It is convenient for shared work, but the more files there are, the slower access to them can get (IBM (opens in a new tab)).
Object storage has no folders at all. Each object is stored whole, with a unique identifier and metadata (data about the object itself), and if it changes it is usually rewritten in full (SNIA (opens in a new tab)). Access goes through HTTP interfaces, above all Amazon S3, which IBM calls the de facto standard. It is used for backups, long-term retention, large sets of varied data for analytics (data lakes) and datasets for model training (IBM (opens in a new tab)).
| Type | How the server sees it | Protocols | Typical uses |
|---|---|---|---|
| Block | as its own disk | Fibre Channel, iSCSI | databases, virtual machines |
| File | as shared folders | SMB, NFS | department and branch file shares |
| Object | as objects with identifiers | S3 (HTTP) | backups, archives, analytics and AI data |
In practice one organization often needs two or three types at once. Many storage systems (arrays) combine block and file access in a single system, while object storage is deployed separately, for example on NetApp StorageGRID or Dell ObjectScale. For HPC/AI, parallel file systems, which many nodes work with at once, are the usual choice. IBM, for example, offers Storage Scale as a data platform for AI, HPC and analytics (IBM (opens in a new tab)).
Performance: all-flash or hybrid
Flash-only (all-flash) arrays deliver lower latency than disk-based systems. NetApp lists databases and virtualization among the main all-flash use cases (NetApp (opens in a new tab)). A hybrid array (flash plus hard drives) gives the same capacity for less. It copes well where data is read rarely or in large streams, such as file archives, video and backups. Mid-sized server rooms often do exactly that: all-flash for databases and virtual machines, a hybrid array or disk shelf for files.
Before choosing, measure your current storage at peak hours. Operations, latency and data written per day are visible in the virtualization software (hypervisor) or in the array itself, and sizing from them is more reliable than from anyone’s estimates.
Deduplication (removing repeated data) and compression reduce the physical capacity you need, but the result depends on the data. In a support article for its backup systems, Dell explains why the reduction ratio (how many times the volume shrinks) can be low: the data is already compressed or encrypted before it reaches the storage, by the backup application, or by the file format itself, as with PDF, audio, video and image files (Dell (opens in a new tab)). So test the ratio on your own data and size capacity with headroom in case it comes out lower.
Capacity and growth
Calculate the current volume of each data group, its growth rate over the last year or two, and space for snapshots. Usable capacity is lower than raw: RAID (protective grouping of drives), spare drives and system areas take their share. How much depends on the protection scheme and the vendor, so compare quotes by usable capacity before deduplication: “effective” capacity in a quote is a forecast, not a guarantee. Watch the units too: a TiB (binary terabyte) is almost 10% larger than a TB, so compare in the same units.
Thin provisioning lets you allocate space to volumes as it is needed instead of reserving it in advance (NetApp (opens in a new tab)). This saves capacity, but actual disk usage has to be monitored so that space doesn’t run out unexpectedly. Check the acceptable fill threshold in the documentation for your array or storage software: Broadcom, for example, recommends keeping about 30% of capacity free in its VMware vSAN software-defined storage (Broadcom (opens in a new tab)).
A controller-based array (controllers are the units that handle requests to the drives) grows with disk shelves, a scale-out system with new nodes, and in the latter performance grows along with capacity. In a controller-based array the controllers themselves limit performance, so find out whether the platform supports upgrading controllers to a new generation without migrating data.
Resilience and backups
RAID survives a drive failure, redundant controllers and paths survive a component failure, and replication to a second site survives the loss of a site. These mechanisms don’t protect against deletion, administrator error or ransomware, because they reproduce unwanted changes too. Veeam separates the tasks this way: a replica is a one-to-one copy of a virtual machine for fast failover, while backups serve long-term retention, immutability and granular file- or application-level recovery (Veeam (opens in a new tab)).
That’s why storage and backup are designed together. Backups get a separate system, independent of the primary array, with immutable copies and one more copy outside the main site. How to protect the copies themselves from ransomware is covered in Backups against ransomware. Security recommendations for the storage infrastructure itself, including data protection, restoration assurance and encryption, are collected in NIST SP 800-209 (NIST (opens in a new tab)). Backup software is described on the Software page.
Power and shutdown
The array is shut down last, after virtual machines and servers, and started first – both in a planned shutdown and when power fails. Check that the uninterruptible power supply (UPS) can shut the array down through its software and that the controller cache is protected against power loss. How to size the UPS is covered in How to choose a UPS for a server room.
A hyperconverged system instead of a separate array
Hyperconverged infrastructure (HCI) combines compute, networking and storage in one platform. The cluster grows by adding nodes, and typical use cases are virtualization and branch offices (HPE (opens in a new tab)). Storage here is software-defined: it runs on the servers’ own drives, so a separate array is usually not needed. This option is worth considering if almost all of the workload is virtual machines and you prefer to manage a single cluster. Just remember, when comparing HCI with a separate array, to count hypervisor and software-defined storage licenses over the whole service life. These licensing terms have changed noticeably in recent years, so use the current ones: they may decide which option costs less.
That said, HCI doesn’t suit every application (IBM (opens in a new tab)). A separate array is usually a better fit when capacity must grow much faster than compute, when physical servers outside the cluster use the storage, or when large file or object volumes are required. Servers for hyperconverged clusters are described on the Servers & Compute page.
Support and service life
Choose support terms together with the storage. Ask how many years of support you can buy, how fast failed components are replaced and whether support can be extended after the initial term. And be sure to ask where spare parts will come from and how many days they really take to reach Ukraine, and whether there is a service engineer on site. For critical systems, keep your own set of spare drives and power supplies at the site. Also check that the array is compatible with your hypervisor and backup software.
Service life also depends on where the platform is in its lifecycle. For example, for NetApp arrays running ONTAP, new feature releases support a platform for two more years after its end of availability, and support typically ends five years after end of availability (NetApp (opens in a new tab)). Other vendors have their own terms. If you buy a platform that is about to be withdrawn from sale, you get a shorter update window, so ask for the end-of-availability date before signing the specification.
Storage classes and vendor families are on the Enterprise Storage page, and storage as part of the server room is covered on the Data Center page. DIXI-CENTER can draw up these requirements with you and then select, deliver and set up the storage.
What to include in your email
- the list of systems and data that will use the storage, with current volumes
- data growth over the last year or two
- RPO and RTO for the main systems, agreed with the business process owners
- peak-hour workload figures: operations, latency, write volume
- existing servers, hypervisor, storage network (SAN: Fibre Channel or iSCSI, port speed) and backup software
- whether there is a second site and what link connects it
- how systems are shut down during power outages
- the expected service life, support requirements and delivery timeline
These points are already in the email – just add your answers.
Sources
- NIST CSRC Glossary: Recovery Point Objective
- NIST CSRC Glossary: Recovery Time Objective
- IBM: What is block storage?
- IBM: What is file storage?
- SNIA: What is Object Storage?
- IBM: What is object storage?
- IBM Storage Scale
- NetApp: What is flash storage?
- Dell: Troubleshooting poor deduplication and compression ratio of files on Data Domain Restorers
- NetApp ONTAP: Storage efficiency overview
- Broadcom KB: vSAN Health Service – Physical Disk Health – Disk Capacity
- Veeam: Putting the Replication in Veeam Backup & Replication
- NIST SP 800-209: Security Guidelines for Storage Infrastructure
- HPE: What is hyperconverged infrastructure?
- IBM: What is hyperconverged infrastructure?
- NetApp KB: Why does the latest software release not support my hardware or platform