Power distribution
Rack PDUs (power distribution units) with metering and control, automatic transfer switches.
Rack UPS and battery modules
Double-conversion units for server rooms, expansion modules for longer runtime.
Rack UPS and battery modules
Double-conversion units for server rooms, expansion modules for longer runtime.
UPS for workplaces and small offices
Standby and line-interactive (voltage-regulating) units for computers, point-of-sale terminals and network cabinets.
Hybrid inverters and energy storage
Inverter, batteries and solar panels in one system, with cloud monitoring.
What it is and who it’s for
Uninterruptible power supplies (UPS), batteries, hybrid inverters and power distribution for server rooms, network equipment and workplaces. The choice depends on what must keep running during an outage, for how long, and with what level of redundancy. A UPS is enough for a short outage and a clean shutdown; several hours of work need larger battery systems; long outages also need a generator. Monitoring lets equipment shut down in time if power doesn’t come back.
Use cases
Backup power is sized from what must keep running without the grid, and for how long.
-
Server room, network and data center
Servers, storage and switches must ride through a short outage without rebooting and shut down cleanly in a long one. Server rooms and data centers need three-phase UPS systems, redundancy and power distribution to the racks.
-
Workplaces and point of sale
A computer, monitor, cash register or receipt printer, so that work is saved and the shift can be closed.
-
The office during blackouts
Several hours of network, Wi-Fi, laptops and lighting from a battery system or a generator.
-
Branches and remote sites
Shops, warehouses, telecom sites: power without an engineer on duty, with remote monitoring.
-
Solar generation and storage
Hybrid inverters that combine the grid, solar panels and batteries.
-
Field teams and temporary sites
Portable power stations for field work, events and pop-up sites.
Product families
From a UPS for a single workstation to energy storage systems; the load and the runtime you need decide the model.
-
UPS for workplaces and small offices
Standby and line-interactive (voltage-regulating) units for computers, point-of-sale terminals and network cabinets.
-
Rack UPS and battery modules
Double-conversion units for server rooms, expansion modules for longer runtime.
-
Three-phase UPS
For server rooms, data centers and production, with modular redundancy.
-
Hybrid inverters and energy storage
Inverter, batteries and solar panels in one system, with cloud monitoring.
-
Portable power stations
Mobile power for field work, temporary sites and workplace backup.
-
Power distribution
Rack PDUs (power distribution units) with metering and control, automatic transfer switches.
-
Monitoring and management
Network cards, alerts and automatic equipment shutdown.
-
Generators
For long outages.
Manufacturer series APC Back-UPS, rack PDUs, EcoStruxure; Eaton Tripp Lite series; Deye hybrid and off-grid inverters, All-in-One ESS, Modular C&I ESS, Deye Cloud; Bluetti portable power stations, home and commercial energy storage
Manufacturers we work with
The power equipment manufacturers we work with.
How to choose
We start with the list of loads.
What to keep running, and for how long
We list the equipment that must work without the grid and the runtime you need. A UPS is enough for short outages and a clean shutdown; several hours of work need larger battery systems; long outages also need a generator with automatic transfer.
UPS type
Standby UPS units switch to battery on failure and suit desktop computers and home networks. Line-interactive units also regulate voltage, for workplaces and network cabinets. Online double-conversion units power the load through the inverter all the time, with no transfer time to battery, and suit mission-critical equipment in server rooms and data centers (Eaton (opens in a new tab)).
Capacity and headroom
UPS capacity is stated in volt-amperes (VA) and watts (W), and the load must be checked against both. We size from the equipment’s actual consumption, not from the power supply label, and leave headroom: Schneider Electric recommends loading a UPS to around 80% of its maximum capacity and not running it at full capacity for long (Schneider Electric (opens in a new tab)). Headroom also affects runtime.
Batteries
Lead-acid (VRLA) batteries are cheaper; lithium iron phosphate (LiFePO4) batteries are lighter, last more cycles and suit daily outages better. According to APC, most of its lead-acid batteries last three to five years, and every 8 °C above the optimal 20–25 °C halves that life (APC (opens in a new tab)). It’s worth building the replacement date into the plan from the start; under a service contract, we remind you when it’s due. Batteries are matched to the voltage of the specific inverter, for example 48 V or 24 V (Deye (opens in a new tab)).
Redundancy and distribution
Servers with two power supplies connect to two power distribution units (PDUs) on independent power feeds (A and B); single-supply devices get an automatic transfer switch. Critical systems get UPS units with a spare module (N+1), so servicing or losing one module doesn’t drop the load.
Monitoring and safety
A UPS network card sends alerts and triggers a clean shutdown of servers and virtual machines if power doesn’t come back. Batteries need ventilation and temperatures within the manufacturer’s limits; large battery systems are subject to separate room and fire safety requirements.
Integration and service
We size the load, install the UPS in the rack, configure it and test it on battery. We don’t do electrical installation or power lines.
- Sizing Load list, required runtime, UPS type, batteries and wiring.
- Supply UPS units, batteries, inverters, PDUs and accessories in one specification.
- Installation and setup Rack installation of UPS units, setup of monitoring and automatic shutdown.
- Load testing After installation, we test the switch to battery and the real runtime – only then does it go live.
- Warranty and support We handle warranty claims through the manufacturer’s authorized service centers and provide support after rollout.Warranty serviceTechnical support
- Replacement batteries and upgrades Replacement batteries, modules for more capacity, new equipment.
How to choose: practical guides
Describe the task and we’ll size your backup power
Send us an email and we’ll work out the details and suggest options. It helps to include:
- what must run without the grid (a list of equipment or its consumption)
- how long it must run on its own
- whether the site has single-phase or three-phase supply
- whether you have solar panels or a generator
- where the equipment will stand and what the temperature is there
- what backup power you already have and how old the batteries are
- delivery dates and location, and your budget range